X-Ray Flaw Detector
Industrial Testing X-ray Flaw Detector With 322~92 Mm / Min Inlet Velocity
HUATEC NDT HDL-430L industrial testing X Ray film developer (1) professional grade industrial flaw detector HDL-430L NDT HDL-430L industrial ray film washing machine is our company's independent research and development products for two years. According to the new products developed by GB/T4730-2005 "non destructive testing of pressure equipment" and GB/T15786-2002 "industrial ray film flushing machine", our company has independent intellectual property rights. The NDT HDL
Industrial Film View Lamp , Led Film View Machine Nonpolar Continuous Dimming
HFV-2008 Industrial film view lamp HFV-2008 de force LED industrial film observation lamp is a new product developed by the latest standard for JB/T4730-2005 "non destructive testing of pressure equipment" and GB/T 19802-2005 "industrial radiographic negative film lamp". The imported ultra high power LED (SMD) was used as the light source of the viewing lamp. The tiny defects on the 5.0D blackening film can be clearly observed. In the foot switch mode, continuous work for 12
HUATEC-SUPER-3D X-Ray Digital Direct Imaging System Portable X-Ray 3D / 2D Imaging System
HUATEC-SUPER-3D X-ray digital direct imaging system Portable X-ray 3D / 2D Imaging System High-end quality, quality assurance Upper left:The SUPER-3D resolution with standard "wire pair gauge" is 3.6 LP / mm. Lower Right:For comparison, the lower left figure is the standard resolution of the standard X-ray imager, about 1.1 LP / mm. From the top left, we can see SUPER-3D system with ultra-high definition. HUATEC-SUPER -3D see the objects hidden in heavy objects Left: X-ray
0.025eV~20MeV X-Ray Flaw Detector Both Wall Handheld Radiation Neutron Survey Meter
HUATEC DL805-N Network Neutron radiation monitoring system mainly for radioactive workplace for online real-time monitoring of X-ray, gamma rays, and consists of a monitoring controller and multiple detectors. Between controller and detector uses the 485 industrial control bus communication connection can also be connected by wireless network communication. Real-time reflect the dose rate of each probe points. Instrument characteristics Controller uses a high-speed embedded
Film Illuminator Negatoscope Industry Film Viewer HFV-700C 14”x17” 360×430mm
Large size Industry Film Viewer HFV-700C 14”x17” The excellent selected material the viewer’s viewing screen and optical path material are all adopted of Acrylic glass plate manufactured by Japan Mitsubishi Liyan Co. Beyond the glass has a light transmittance and durability to ensure the non-deformation, do not change color. Using the latest technology abroad It adopts the newest backlighting technology of color LED Standards conforming: GB/T4730-2005, GB/T7903-1999 The size
Film illuminator HUATEC Ultra-thin Industry Film Viewer HFV-700B Negatoscope
Ultra-thin Industry Film Viewer HFV-700B The excellent selected material the viewer’s viewing screen and optical path material are all adopted of Acrylic glass plate manufactured by Japan Mitsubishi Liyan Co. Beyond the glass has a light transmittance and durability to ensure the non-deformation, do not change color. Using the latest technology abroad It adopts the newest backlighting technology of color LED Standards conforming: GB/T4730-2005, GB/T7903-1999 Technical
Small, Light X-Ray Flaw Detector Identification (PMI) Si-PIN Detector HXRF-120
HUATEC Hand-held Alloy Analyzer Alloy Material Identification (PMI) Si-PIN Detector HXRF-120 Performance Features 1. Small, light and easy to carry. 2. High-speed processing chip, advanced algorithm and high-responsive software, resulting in even faster analysis. 3. High-performance X-ray Tube, Ultra-high Resolution Detector combined with Digital Multi-channel Processing Technology, yielding super-high detection resolution. 4. Indicator lights flash on both sides for safety
X Ray Metal Tube for Non Destructive X Ray Inspection System 160KVp 4mA
Specifications of the x ray metal tube for x ray inspection system X RAY TUBE (METAL) No. Model Tube voltage(KVp) Tube current(mA) Focus point(mm) Filament voltage(V) Filament current(A) Radiant angle Model applied 1 HX-160(A) 160 4/19 0.4/3.0 4.2/5.5 4.1/4.2 40°+5° XYD-160 2 HX-160(B) 160 4/10 0.4/1.5 4.2/5.5 4.1/4.2 40°+5° XYD-160 3 HX-160(C) 160 4/4 0.4/0.4 4.2 4.1 40°+5° XYD-160 4 HX-160(D) 160 10/10 1.5/1.5 5.5 4.2 40°+5° XYD-160 5 HX6-160 160 6 0.3×3.0 2.7 4.2 25°×360°
X Ray Tube for Airport X Ray Safe Examination Inspection System 160KVp 4mA
Specifications for the x ray glass tube for airport x ray safe examination inspection system Number Model Technical parameters Beam angle Size Tube voltage (kVp) Tube current (mA) Focus sport(mm) Filament voltage(V) Filament current(A) 1 H33A 160 2 0.8×0.8 5.3 4.4 40°+5° Glass: Φ68mm,Total length:190mm 2 H33B 160 4 0.3×0.8 4 3.5±0.2 110°×4° Glass:Φ68mm, Total length:190mm 3 H33C 160 4 2.5×0.8 3.5±0.2 3.7±0.2 110°×20° Glass:Φ68mm, Total length:190mm 4 H33D 160 2 0.8×0.8 3.5±0