Highlight:

DC AC Milligauss Meter

,

Magnetic Field Milligauss Meter

,

Desk Type Digital Gauss Meter

Testing Range:
0~200mT~2000mT
Accuracy:
±1%
Distinguishing Power:
0.01mT, 1mT
Magnetic Field Measured:
DC Magnetic Field (static Magnetic Field), AC Magnetic Field (dynamic Magnetic Field)
Unit:
MT/Gs Unit Changing
Size:
230mm×205mm×80mm
Weight:
1.5kg
Product Name:
Desk Type Gauss Meter
Display:
41/2 LCD, N,S Pole Automatic Display
AC/DC Function:
Switchable
Display Unit:
MT GS Note: 1mT=10Gs
Testing Range:
0~200mT~2000mT
Accuracy:
±1%
Distinguishing Power:
0.01mT, 1mT
Magnetic Field Measured:
DC Magnetic Field (static Magnetic Field), AC Magnetic Field (dynamic Magnetic Field)
Unit:
MT/Gs Unit Changing
Size:
230mm×205mm×80mm
Weight:
1.5kg
Product Name:
Desk Type Gauss Meter
Display:
41/2 LCD, N,S Pole Automatic Display
AC/DC Function:
Switchable
Display Unit:
MT GS Note: 1mT=10Gs
Product Description

MT GS Conversion DC AC Magnetic Field Desk Type Precision Mill Gauss Meter HGS-20C

 

HGS-20C desktop digital Gauss meter can be used to measure DC, AC magnetic field. Mainly used in the surface magnetic field of permanent magnet materials, DC motor, loudspeaker, magnetic separator, permanent magnet remover working magnetic field. In addition, it can be used to detect the residual magnetism of items after machining, detect the distribution of magnetic poles, detect the residual magnetic field of products after demagnetization, control the magnetic condition of electroplating items, detect the magnetic flux of motors, and detect the magnetic leakage of electromagnetic fields. And the magnetic induction intensity of various magnetic fields. The instrument has wide range, easy operation and clear LCD display. It is a special instrument for detecting the intensity of various magnetic fields in space.

 

Range of application

It is used to measure the surface remanence and dc magnetic field of steel tube, cast iron and other workpieces. The hall sensor can be equipped with longitudinal and transverse sensors according to customers' requirements.

 

Technical indicators

Range: 0~200mT~2000mT

Basic error: ±2% ±3 words (less than 1000mT)

±5% ±3 words (over 1000mT) (can be made by basic error ±1% upon request)

Distinguishing power: 0.01mT, 1mT

Magnetic field measured: DC magnetic field (static magnetic field), AC magnetic field (dynamic magnetic field)

Function description: With hold, AC LCD display. With sorting function (by setting the upper and lower limits of the measured magnetic field on the panel, you can light up when measuring high, low, qualified) MT GS conversion.

Ambient temperature: 5 ° C to 40 ° C

Relative humidity: 20%~80% (no condensation)

Power supply: AC220V 50Hz

Size: 230mm×205mm×80mm

Instrument weight: 1.5Kg

Display mode: 41/2 LCD, N,S pole automatic display

Display unit: MT GS Note: 1mT=10Gs

 

 

Operation request:

  1. Magnetic field distribution of material surface
  2. Working magnetic field produced fro some instrument that as iron-removing device,magnet-selecting machine, magnet chuck, magnet spool and demagnetizing coil
  3. Leakage Magnetic iron-surface
  4. Do not use the instrument in unappropriate conditions.
  5. If you find the value of testing were error in the status ofmeasurement,

    you could loosened the handle of the probe to adjust the screw of the resistance tinily.

  6. If don’t ensure that the instrument is operated correctly described below, there would be error or mistake

  7. Don’t attempt to repair, or disassemble, and any reconstruct this instrument.

  8. Use only recommended power accessories.
  9. Don’t connect the terminals of the outer power supply reversely. the inner is plus, the outer is minus.
  10. Don’t drop this instrument or the probe down ground. It’ll be damaged by strong vibration.
  11. Do not allow hands or other objects with dirt to touch the probe.
  12. Avoid using, placing or storing the instrument in places subject to strong sunlight or high temperature, so as to humidity, water, oil, rust air, vibration and others.

MT GS Conversion DC AC Milligauss Meter Magnetic Field Desk Type Precision HGS-20C 0MT GS Conversion DC AC Milligauss Meter Magnetic Field Desk Type Precision HGS-20C 1MT GS Conversion DC AC Milligauss Meter Magnetic Field Desk Type Precision HGS-20C 2