Product Description

MT GS Conversion DC AC Magnetic Field Desk Type Precision Mill Gauss Meter HGS-20C

 

HGS-20C desktop digital Gauss meter can be used to measure DC, AC magnetic field. Mainly used in the surface magnetic field of permanent magnet materials, DC motor, loudspeaker, magnetic separator, permanent magnet remover working magnetic field. In addition, it can be used to detect the residual magnetism of items after machining, detect the distribution of magnetic poles, detect the residual magnetic field of products after demagnetization, control the magnetic condition of electroplating items, detect the magnetic flux of motors, and detect the magnetic leakage of electromagnetic fields. And the magnetic induction intensity of various magnetic fields. The instrument has wide range, easy operation and clear LCD display. It is a special instrument for detecting the intensity of various magnetic fields in space.

 

Range of application

It is used to measure the surface remanence and dc magnetic field of steel tube, cast iron and other workpieces. The hall sensor can be equipped with longitudinal and transverse sensors according to customers' requirements.

 

Technical indicators

Range: 0~200mT~2000mT

Basic error: ±2% ±3 words (less than 1000mT)

±5% ±3 words (over 1000mT) (can be made by basic error ±1% upon request)

Distinguishing power: 0.01mT, 1mT

Magnetic field measured: DC magnetic field (static magnetic field), AC magnetic field (dynamic magnetic field)

Function description: With hold, AC LCD display. With sorting function (by setting the upper and lower limits of the measured magnetic field on the panel, you can light up when measuring high, low, qualified) MT GS conversion.

Ambient temperature: 5 ° C to 40 ° C

Relative humidity: 20%~80% (no condensation)

Power supply: AC220V 50Hz

Size: 230mm×205mm×80mm

Instrument weight: 1.5Kg

Display mode: 41/2 LCD, N,S pole automatic display

Display unit: MT GS Note: 1mT=10Gs

 

 

Operation request:

  1. Magnetic field distribution of material surface
  2. Working magnetic field produced fro some instrument that as iron-removing device,magnet-selecting machine, magnet chuck, magnet spool and demagnetizing coil
  3. Leakage Magnetic iron-surface
  4. Do not use the instrument in unappropriate conditions.
  5. If you find the value of testing were error in the status ofmeasurement,

    you could loosened the handle of the probe to adjust the screw of the resistance tinily.

  6. If don’t ensure that the instrument is operated correctly described below, there would be error or mistake

  7. Don’t attempt to repair, or disassemble, and any reconstruct this instrument.

  8. Use only recommended power accessories.
  9. Don’t connect the terminals of the outer power supply reversely. the inner is plus, the outer is minus.
  10. Don’t drop this instrument or the probe down ground. It’ll be damaged by strong vibration.
  11. Do not allow hands or other objects with dirt to touch the probe.
  12. Avoid using, placing or storing the instrument in places subject to strong sunlight or high temperature, so as to humidity, water, oil, rust air, vibration and others.

MT GS Conversion DC AC Milligauss Meter Magnetic Field Desk Type Precision HGS-20C 0MT GS Conversion DC AC Milligauss Meter Magnetic Field Desk Type Precision HGS-20C 1MT GS Conversion DC AC Milligauss Meter Magnetic Field Desk Type Precision HGS-20C 2

Overall Rating
5.0
★★★★★
★★★★★
Based on 50 reviews recently
5 star
100%
4 star
0
3 star
0
2 star
0
1 star
0
All Reviews
  • 1
    12
    Brazil Oct 29.2025
    ★★★★★
    ★★★★★
    123
You May Also Like
Quality Pipe Corrosion Detection Spark Detector, Porosity Holiday Detector elcometer holiday detector factory
Video

Pipe Corrosion Detection Spark Detector, Porosity Holiday Detector elcometer holiday detector

Pipe Corrosion Detection Spark Detector, Porosity Holiday Detectors Holiday Detector Test HD-101 Porosity Detector is employed in the non-destructive detection and location of pinholes, bare spots or thin points in protective coatings applies for corrosion protection over metal and concrete (conductive) surfaces. With corrosion an extremely costly and disruptive worldwide problem, preventative determination becomes essential. For newly constructed tanks, pipelines and other
Quality Ultrasonic Depth Gauge Ultrasonic Thickness Gauge , UT Thickness Gage Ultrasonic Wall Thickness Measurement factory
Video

Ultrasonic Depth Gauge Ultrasonic Thickness Gauge , UT Thickness Gage Ultrasonic Wall Thickness Measurement

Ultrasonic Depth Gauge Ultrasonic Thickness Gauge , UT Thickness Gage Ultrasonic Wall Thickness Measurement Features 1.Capable of performing measurements on a wide range of material, including metals, plastic, ceramics, composites, epoxies, glass and other ultrasonic wave well-conductive materials. 2.Transducer models are available for special application, including for coarse grain material and high temperature applications. 3.Probe-Zero function, Sound-Veloctiy-Calibration
Quality Pocket Thickness Gauge Ultrasonic Thickness Measurement for Steel plate Pipe wall thickness factory
Video

Pocket Thickness Gauge Ultrasonic Thickness Measurement for Steel plate Pipe wall thickness

Ultrasonic Probe Ultrasonic Thickness Measurement for Chemical Equipment Special design: inbuilt probe, without cable Application: Ultrasonic thickness gauge TG-2930 is used for measuring thickness and corrosion of pressure vessels, chemical equipment, boilers, oil storage tanks, etc.in industries of petroleum, shipbuilding, power station, and machine manufacturing. Measuring range (metric/imperial): 1.0-200mm, 0.05-8inch Operating principle: ULTROSONIC Materials measured:
Quality Eddy Current 0 - 2000um 0.1mm Coating Thickness Gauge TG-2000 Micron Thickness Gauge factory
Video

Eddy Current 0 - 2000um 0.1mm Coating Thickness Gauge TG-2000 Micron Thickness Gauge

Description: With in-built or separate probe(s) Function: TG-2000F (ferrous substrate) TG-2000N (non ferrous substrate) TG-2000FN (2 in 1, F & NF type) Operating principle: magnetic induction/eddy current (F/NF) Measuring range:0-2000um/0-50mil Resolution; 0.1/1 Accuracy: ±1-3%n or ±2.5um Min. measuring area: 6mm Min. sample thickness: 0.3mm Battery indicator: low battery indicator Metric/ imperial: convertible Power supply: 4x1.5V AAA(UM-4)battery Auto power off Operating
Contact Us
You Can Contact Us At Anytime!