3000mt Automatic Calibration Magnetic Field Strength Meter Digital Hall Effect Tesla Magnetometer Hgs-106

Contact me for free samples and coupons.
WhatsApp:0086 18588475571
Wechat: 0086 18588475571
skype: sales10@aixton.com
If you have any concern, we provide 24-hour online help.
xTesting Range | 0-300mT~ 3000mt | Accuracy | 0~100mT 1%, 2% Above 100mT (measured In Uniform Magnetic Field) |
---|---|---|---|
Sensitivity | DC×1:0.00 ~ 300.00mT. 0.01mT DC× 10:0.0 ~ 3000.0mt 0.1mt | AC Magnet Field | 10-200Hz |
Unit | MT/Gs Unit Changing | Size | 150mm×70mm×30mm |
Weight | 500g | Product Name | Magnetometer |
Measured Magnetic Field | DC Static Magnetic Field, AC Dynamic Magnetic Field | Battery | AA Dry Battery 4pcs |
Pick Function | Peak Maintenance Function | Zero Calibration | Automatic Zero Adjustment |
Highlight | automatic calibration magnetic field strength meter,digital magnetic field strength meter,hall effect magnetic field strength meter |
3000mT Automatic Calibration Digital Magnetic Field Strength Meter Hall Effect Tesla Magnetometer HGS-106
HGS-106 is a handheld digital gauss meter controlled by single chip microcomputer, which can be used to measure the magnetic induction intensity of dc magnetic field, radiation magnetic field and other magnetic fields. The instrument can be carried around, with a wide range, easy operation and clear LCD display. It has many functions, such as measuring/peak maintaining, MT/GS unit conversion, automatic zero adjustment by push button, 300MT/3000MT range conversion, etc.
Main technical indicators
1. Measuring range: 0~300mT~ 3000mt
2. Frequency range: 10Hz~200Hz
3. Accuracy: 0~100mT 1%, 2% above 100mT (measured in uniform magnetic field)
4. Resolution: DC×1:0.00 ~ 300.00mT. 0.01mT
DC× 10:0.0 ~ 3000.0mt 0.1mt
5. Measured magnetic field: dc magnetic field (static magnetic field)
6. Function description: peak maintenance function
Gs (gauss) /mT (millitesla) can be switched freely
7. N/S polarity display during dc measurement. N for positive and S for negative
8. Display button fast automatic zero
9. Ambient temperature: 5℃~40℃
10. Relative humidity: 20%~80% (no condensation)
11. Power supply: four no.5 batteries are externally connected with voltage stabilizing power
12. External size: 150mm (L) ×70mm (W) ×30mm (H)
13. Instrument weight: 450g
14. Display mode: 41/2 LCD
15. Display unit: mT/Gs
16. AC/DC switchable
Operation request:
- Magnetic field distribution of material surface
- Working magnetic field produced fro some instrument that as iron-removing device,magnet-selecting machine, magnet chuck, magnet spool and demagnetizing coil
- Leakage Magnetic iron-surface
- Do not use the instrument in unappropriate conditions.
-
If you find the value of testing were error in the status ofmeasurement,
you could loosened the handle of the probe to adjust the screw of the resistance tinily.
-
If don’t ensure that the instrument is operated correctly described below, there would be error or mistake
-
Don’t attempt to repair, or disassemble, and any reconstruct this instrument.
- Use only recommended power accessories.
- Don’t connect the terminals of the outer power supply reversely. the inner is plus, the outer is minus.
- Don’t drop this instrument or the probe down ground. It’ll be damaged by strong vibration.
- Do not allow hands or other objects with dirt to touch the probe.
- Avoid using, placing or storing the instrument in places subject to strong sunlight or high temperature, so as to humidity, water, oil, rust air, vibration and others.