Product Description

5 Points Chrome Plating​ Test Block Penetrant Testing Block Test Specimen YM-C Type C

 

Model:YM-C type C

All linear dimensions to the requirements of AS2083/2005, BS2704/1978/1983, where applicable. Heat treatment to the requirements of GB/T6394/2002. where practicable tolerances to (+/-0.1mm) unless otherwise stated. Treated to 920 degrees C for 30 minutes, water quenched, 650 degrees C for 3 hours, air cooled

Material standard:according to ISO 10474-3.1.B,JIS G 0415-3.1.B

Depth:100µm

Width target value:0.5µm

Test standard: GB/T23911-2009,JB/T6064-2006,ASME

 

Type A test block is suitable for sensitivity comparison test of two different penetrant flaw detection agents in the case of non-contamination, and is also suitable for sensitivity comparison test of the same penetrant flaw detection agent in A different process. However, due to the large size of the crack, it can not be used for the performance identification of highly sensitive testing agent.

 

Type B test block is mainly used to verify the sensitivity of operation method and process system; It is usually used against plastic reproductions or photographs.

 

Type C test blocks are used for the same purposes as Type A test blocks, but mainly to identify various penetrant properties and determine the sensitivity level, because the crack width and depth of Type C test blocks can be controlled.

 

5 Points Chrome Plating Penetrant Testing Block YM-C Type C 0

 

Precautions for the use of penetration test blocks

 

1 The penetration test block shall be cleaned with solvent before repeated use; Wash with a hard bristle brush and dry for later use.

 

2 Penetration inspection procedures shall be carried out on the penetration test blocks in accordance with the instructions of the manufacturer of the obtained flaw detection agent.

 

3 Two sets of penetration test blocks shall be used for fluorescence detection and colored penetrant detection respectively, because the fluorescence display of fluorescent penetrant in the test will be affected after the use of colored penetrant.

 

4 After use, it should be cleaned thoroughly in time, and all traces of penetrant flaw detection agent should be eliminated as far as possible, and then soaked in acetone or alcohol for 1-2 hours. Whether the cleaning is timely and thorough after use directly affects the service life of the test block.

 

5 Test blocks should not be placed in a dryer or soaked in anhydrous alcohol.

 

6 The test block shall be replaced in time if it is found that the original feature of the defect cannot be displayed during use

 

Other names of products: stainless steel chrome-plated penetration test block, aluminum alloy quenching penetration test block, surface flaw detection test block

 

 

Standard delivery:

YM-C block 1 set

Calibration certificate 1 pc

Case 1 pc

Overall Rating
5.0
★★★★★
★★★★★
Based on 50 reviews recently
5 star
100%
4 star
0
3 star
0
2 star
0
1 star
0
All Reviews
  • 1
    12
    Brazil Oct 29.2025
    ★★★★★
    ★★★★★
    123
You May Also Like
Quality Pipe Corrosion Detection Spark Detector, Porosity Holiday Detector elcometer holiday detector factory
Video

Pipe Corrosion Detection Spark Detector, Porosity Holiday Detector elcometer holiday detector

Pipe Corrosion Detection Spark Detector, Porosity Holiday Detectors Holiday Detector Test HD-101 Porosity Detector is employed in the non-destructive detection and location of pinholes, bare spots or thin points in protective coatings applies for corrosion protection over metal and concrete (conductive) surfaces. With corrosion an extremely costly and disruptive worldwide problem, preventative determination becomes essential. For newly constructed tanks, pipelines and other
Quality Ultrasonic Depth Gauge Ultrasonic Thickness Gauge , UT Thickness Gage Ultrasonic Wall Thickness Measurement factory
Video

Ultrasonic Depth Gauge Ultrasonic Thickness Gauge , UT Thickness Gage Ultrasonic Wall Thickness Measurement

Ultrasonic Depth Gauge Ultrasonic Thickness Gauge , UT Thickness Gage Ultrasonic Wall Thickness Measurement Features 1.Capable of performing measurements on a wide range of material, including metals, plastic, ceramics, composites, epoxies, glass and other ultrasonic wave well-conductive materials. 2.Transducer models are available for special application, including for coarse grain material and high temperature applications. 3.Probe-Zero function, Sound-Veloctiy-Calibration
Quality Pocket Thickness Gauge Ultrasonic Thickness Measurement for Steel plate Pipe wall thickness factory
Video

Pocket Thickness Gauge Ultrasonic Thickness Measurement for Steel plate Pipe wall thickness

Ultrasonic Probe Ultrasonic Thickness Measurement for Chemical Equipment Special design: inbuilt probe, without cable Application: Ultrasonic thickness gauge TG-2930 is used for measuring thickness and corrosion of pressure vessels, chemical equipment, boilers, oil storage tanks, etc.in industries of petroleum, shipbuilding, power station, and machine manufacturing. Measuring range (metric/imperial): 1.0-200mm, 0.05-8inch Operating principle: ULTROSONIC Materials measured:
Quality Eddy Current 0 - 2000um 0.1mm Coating Thickness Gauge TG-2000 Micron Thickness Gauge factory
Video

Eddy Current 0 - 2000um 0.1mm Coating Thickness Gauge TG-2000 Micron Thickness Gauge

Description: With in-built or separate probe(s) Function: TG-2000F (ferrous substrate) TG-2000N (non ferrous substrate) TG-2000FN (2 in 1, F & NF type) Operating principle: magnetic induction/eddy current (F/NF) Measuring range:0-2000um/0-50mil Resolution; 0.1/1 Accuracy: ±1-3%n or ±2.5um Min. measuring area: 6mm Min. sample thickness: 0.3mm Battery indicator: low battery indicator Metric/ imperial: convertible Power supply: 4x1.5V AAA(UM-4)battery Auto power off Operating
Contact Us
You Can Contact Us At Anytime!