Portable Vibration Tester True RMS Measurement Measuring Vibration Velocity , Displacement

Contact me for free samples and coupons.
WhatsApp:0086 18588475571
Wechat: 0086 18588475571
skype: sales10@aixton.com
If you have any concern, we provide 24-hour online help.
xOverall Accuracy | ±5% | Temperature Range | 0 - 50C |
---|---|---|---|
High Frequency Acceleration | 1000-5000Hz 10% | Battery | 9V 6F22/Rechargeable, 25/10 Hours Of Continuous Operation |
Pickup | Accelerometer With Handheld Probe And/or Magnetic Mount | Dimensions | 13×6×2.3 Cm |
Weight | 200 G | ||
Highlight | vibration analyzer,digital vibration meter |
Portable Vibration Tester True RMS Measurement Measuring Vibration Velocity , Displacement HG908
Features:
Small size, transducer included,
True RMS measurement.
Measuring parameters: vibration velocity, displacement,acceleration and high-frequency acceleration
Battery powered,
Accelerometer may be integrated or external cable connected.
One button control both power and measurement.Very easy to use.
3 1/2 LCD digital display, sampling per second.
Holding function.
Automatic power off.
Suitable for monitoring machinery vibration caused by imbalance,misalignment, gear & bearing faults and etc.
Specifications:
Testing ranges:
Displacement 1—1999 m m (or 200 mil) Eq. peak-peak
Velocity 0.1—199.9 mm/s (or 20 in/s) true RMS
Acceleration 0.1—199.9 m/s2 (or 20 g) Eq. Peak
High Frequency Acceleration: 0.1—199.9 m/s2 (or 20 g) Eq. Peak
Overall accuracy: ±5%
Temperature range: 0 - 50C
Frequency response:
Displacement 10-1000Hz
Velocity 10-1000Hz
Acceleration 10-1000Hz (908B) 105000Hz (908)
High Frequency Acceleration: 1000-5000Hz 10%
Configuration:
HG908: Separate accelerometer with magnetic mount & probe, long needle probe
Battery: 9V 6F22/Rechargeable, 25/10 hours of continuous operation.
Pickup: Accelerometer with handheld probe and/or magnetic mount
Dimensions: 13×6×2.3 cm; Weight: 200 g
Optional Intrinsically safe version with internal accelerometer