bobAstm E114-15 Inch Type 1018 Calibration Test Block Carbon Steel Mini Iiw 2
-
WilliamAstm E114-15 Inch Type 1018 Calibration Test Block Carbon Steel Mini Iiw 2
-
tomAstm E114-15 Inch Type 1018 Calibration Test Block Carbon Steel Mini Iiw 2
-
LeoAstm E114-15 Inch Type 1018 Calibration Test Block Carbon Steel Mini Iiw 2
Excellent anti-jamming performance X Ray Flaw Detectors for thin iron plate , aluminum

Contact me for free samples and coupons.
WhatsApp:0086 18588475571
Wechat: 0086 18588475571
skype: sales10@aixton.com
If you have any concern, we provide 24-hour online help.
xHighlight | x ray inspection equipment,industrial x ray machine |
---|
Directional radiation portable X-ray flaw detector
(Glass x-ray tube)
XXQ series are suitable for the material directional of thin iron plate, aluminum, rubber and so on, may get very good picture quality and clarity.
Feature:
●Checking the software and hardware itself after start the machine
●Excellent anti-jamming performance, which can adapt for field operation without power supply, because of the motor supports
●Can adjust exposure parameters with keys ( easy operation.)
●Has the function of Delay time opening HV. Convenient for operator keep away from dangerous field
●Can adjust high voltage slowly for protecting X-ray generator
●Automatically controlling according to 1:1 working and rest operating way, the longest continuous exposure period is 5 minutes.
●Including complete protecting system: over KV, over KV, low mA, over mA, over temperature and optical-sound alarming
●Convenient for repairing and maintenance
●Much more Substance for structure designing, much more convenient for local operation
●Time can be changed for±0.3 according to the power supply net to make the exposure more precise
Specification:
|
Output voltage (Kv) |
Input (KW) |
Focus spot (mm) |
Beam angle |
Max penetration (mm) |
Weight (KG) |
Dimensions (mm) |
||
Generator |
Controller |
Generator |
Controller |
||||||
XXQ-1005 |
50-100 |
1.2 |
0.8X0.8 |
40° |
7 |
8.5 |
11 |
Ф135x555 |
350x290x160 |
XXQ-1605 |
60-160 |
1.5 |
0.8X0.8 |
40° |
18 |
17 |
11 |
225x225x600 |
350x290x160 |
XXQ-2005 |
100-200 |
2.0 |
1.5X1.5 |
40°+5° |
29 |
22.5 |
11 |
280x280x650 |
350x290x160 |
XXQ-2505 |
150-250 |
2.5 |
2.0X2.0 |
40°+5° |
39 |
33.5 |
11 |
320x320x740 |
350x290x160 |
XXQ-3005 |
170-300 |
3.0 |
3.5X3.5 |
40°+5° |
50 |
42 |
11 |
335x335x835 |
350x290x160 |
XXQ-3205 |
180-320 |
3.2 |
4.0X4.0 |
40°+5° |
55 |
42 |
11 |
335x335x835 |
350x290x160 |
XXQ-3505 |
200-350 |
3.2 |
4.0X4.0 |
40°+5° |
60 |
42 |
11 |
335x335x835 |
350x290x160 |
Standard Delivery
Directional glass X-ray tube |
1 Pcs |
|
Generator |
1 Set |
|
High voltage joins cable |
1 Pcs |
25 Meters |
Controller |
1 Set |
|
Power cable |
1 Pcs |
10 Meters |
Grounding cable |
1 Pcs |
5 Meters |
Accessories |
1 Set |
|
(Including: alarm lamp, 1 Pcs; lead letter, 1 box; Film dark cassettes 5 pcs; intensifying screen 5 pcs; Wire penetrameter (IQI) 1 set; fuse1 pc) |
Panoramicradiation portableX-rayflaw detector
(Glass x-raytube)
XXH series are suitable for the welding line detection of little pipe.
Installing carrying wheel or pipeline creeping device, convenient to set up in pipeline (controller also may enter pipeline with generator together), once exposure complete one week welding line detection.
Feature:
●Checking the software and hardware itself after start the machine
●Excellent anti-jamming performance, which can adapt for field operation without power supply, because of the motor supports
●Can adjust exposure parameters with keys ( easy operation.)
●Has the function of Delay time opening HV. Convenient for operator keep away from dangerous field
●Can adjust high voltage slowly for protecting X-ray generator
●Automatically controlling according to 1:1 working and rest operating way, the longest continuous exposure period is 5 minutes.
●Including complete protecting system: over KV, over KV, low mA, over mA, over temperature and optical-sound alarming
●Convenient for repairing and maintenance
●Much more Substance for structure designing, much more convenient for local operation
●Time can be changed for±0.3 according to the power supply net to make the exposure more precise
Specification:
|
Output voltage (Kv) |
Input (KW) |
Focus spot (mm) |
Beam angle |
Max penetration (mm) |
Weight (KG) |
Dimensions (mm) |
||||
Level target |
Cone target |
Level target |
Cone target |
Generator |
Controller |
Generator |
Controller |
||||
XXH-1005 |
50-100 |
1.2 |
1.0x3.5 |
25°+5° |
|
8 |
|
8.5 |
9.4 |
Ф135x555 |
305x338x140 |
XXH-1605 |
60-160 |
1.5 |
1.0x3.5 |
25°+5° |
|
11 |
|
17 |
11 |
225x225x600 |
350x290x160 |
XXH-2005 |
100-200 |
2.0 |
1.0x3.5 |
25°+5° |
30°+5° |
27 |
24 |
22.5 |
11 |
280x280x650 |
350x290x160 |
XXH-2505 |
150-250 |
2.5 |
1.0x2.4 |
25°+5° |
30°+5° |
37 |
34 |
33.5 |
11 |
320x320x740 |
350x290x160 |
XXH-3005 |
170-300 |
3.0 |
1.0x3.5 |
25°+5° |
30°+5° |
47 |
40 |
42 |
11 |
335x335x835 |
350x290x160 |
XXH-3205 |
180-320 |
3.2 |
1.0X4.0 |
25°+5° |
30°+5° |
50 |
45 |
42 |
11 |
335x335x835 |
350x290x160 |
XXH-3505 |
200-350 |
3.2 |
1.0X4.0 |
25°+5° |
30°+5° |
55 |
52 |
42 |
11 |
335x335x835 |
350x290x160 |
Standard Delivery
Directional glass X-ray tube |
1 Pcs |
|
Generator |
1 Set |
|
High voltage joins cable |
1 Pcs |
25 Meters |
Controller |
1 Set |
|
Power cable |
1 Pcs |
10 Meters |
Grounding cable |
1 Pcs |
5 Meters |
Accessories |
1 Set |
|
(Including: alarm lamp, 1 Pcs; lead letter, 1 box; Film dark cassettes 5 pcs; intensifying screen 5 pcs; Wire penetrameter (IQI) 1 set; fuse1 pc) |
Directional radiation portable X-ray flaw detector
(Ceramic X-ray Tube)
XXGseries areceramic X-ray tube, both can be directional model and Panoramic, it is more durable than the glass tube: shake proof and long working life.
Feature:
●Checking the software and hardware itself after start the machine
●Excellent anti-jamming performance, which can adapt for field operation without power supply, because of the motor supports
●Can adjust exposure parameters with keys ( easy operation.)
●Has the function of Delay time opening HV. Convenient for operator keep away from dangerous field
●Can adjust high voltage slowly for protecting X-ray generator
●Automatically controlling according to 1:1 working and rest operating way, the longest continuous exposure period is 5 minutes.
●Including complete protecting system: over KV, over KV, low mA, over mA, over temperature and optical-sound alarming
●Convenient for repairing and maintenance
●Much more Substance for structure designing, much more convenient for local operation
●Time can be changed for±0.3 according to the power supply net to make the exposure more precise
Specification
|
Output voltage (Kv) |
Input (KW) |
Focus spot (mm) |
Beam angle |
Max penetration (mm) |
Weight (KG) |
Dimensions (mm) |
||
Generator |
Controller |
Generator |
Controller |
||||||
XXG-1605 |
60-160 |
1.5 |
0.8X0.8 |
40°+5° |
18 |
17 |
11 |
225x225x600 |
350x290x160 |
XXG-2005 |
100-200 |
2.0 |
2.0X2.0 |
40°+5° |
29 |
22.5 |
11 |
280x280x650 |
350x290x160 |
XXG-2505 |
150-250 |
2.5 |
2.0X2.0 |
40°+5° |
38 |
33.5 |
11 |
320x320x745 |
350x290x160 |
XXG-3005 |
170-300 |
3.0 |
2.5X2.5 |
40°+5° |
50 |
42 |
11 |
335x335x835 |
350x290x160 |
Panoramic radiation portable X-ray flaw detector
(Ceramic X-ray Tube)
XXGseries areceramic X-ray tube, both can be directional model and Panoramic, it is more durable than the glass tube: shake proof and long working life.
Feature:
●Checking the software and hardware itself after start the machine
●Excellent anti-jamming performance, which can adapt for field operation without power supply, because of the motor supports
●Can adjust exposure parameters with keys ( easy operation.)
●Has the function of Delay time opening HV. Convenient for operator keep away from dangerous field
●Can adjust high voltage slowly for protecting X-ray generator
●Automatically controlling according to 1:1 working and rest operating way, the longest continuous exposure period is 5 minutes.
●Including complete protecting system: over KV, over KV, low mA, over mA, over temperature and optical-sound alarming
●Convenient for repairing and maintenance
●Much more Substance for structure designing, much more convenient for local operation
●Time can be changed for±0.3 according to the power supply net to make the exposure more precise
Specification
|
Output voltage (Kv) |
Input (KW) |
Focus spot (mm) |
Beam angle |
Max penetration (mm) |