• HUATEC GROUP CORPORATION
    bob
    Astm E114-15 Inch Type 1018 Calibration Test Block Carbon Steel Mini Iiw 2
  • HUATEC GROUP CORPORATION
    William
    Astm E114-15 Inch Type 1018 Calibration Test Block Carbon Steel Mini Iiw 2
  • HUATEC GROUP CORPORATION
    tom
    Astm E114-15 Inch Type 1018 Calibration Test Block Carbon Steel Mini Iiw 2
  • HUATEC GROUP CORPORATION
    Leo
    Astm E114-15 Inch Type 1018 Calibration Test Block Carbon Steel Mini Iiw 2
Contact Person : Noah
Phone Number : +8613911115555
WhatsApp : +8613910983110

Compact Design X-Ray Flaw Detector X Ray Film Developer Machine 31kgs Weight

Place of Origin CHINA
Brand Name HUATEC
Certification ISO CE
Model Number HDL-340
Minimum Order Quantity 1
Packaging Details in carton
Payment Terms T/T, Western Union
Supply Ability 500

Contact me for free samples and coupons.

WhatsApp:0086 18588475571

Wechat: 0086 18588475571

skype: sales10@aixton.com

If you have any concern, we provide 24-hour online help.

x
Product Details
The Running Time 6-15min. (10-Gear Adjustable) Inlet Speed 90 Mm/min (6 Minutes When Running Time)
Development Time 90-210 Sec Water Temperature 5~30 Degrees
Size Of Film Min.5x10cm Up To 35cm Width Tank Volume 6 Liters (per Dosing Capacity)
Size 41x52x42cm Weight 31kgs
Power 220-240v6A 50 Or 60Hz
Highlight

welding x ray machine

,

industrial x ray machine

,

x ray inspection equipment

Leave a Message
Product Description

Filed X Ray Film Developer Machine Film Developer Film Processor HDL-340

 

Compact design with small footprint for mobile and filed operations;

Integrated design of development, fixing and drying axle frame system;

The use of non-piping design.

 

 

Technical parameter

1. Size of film: Min.5x10cm up to 35cm width

2. Running time: 6-15min. (10-Gear Adjustable)

3. Inlet speed: 90 mm/min (6 minutes when running time)

4. Development time : 90-210 sec

5. Tank volume :6 Liters (per dosing capacity)

6. Development temperature: 23-35 degrees can be adjusted

7. Fixed temperature : adjusted automatically according to development temperature

8. Drying temperature : 65 degrees

9. Water temperature 5~30 degrees

10. Water consumption: 1.6 L/min in film operation (when rinsing film);Water-free cycle design can also be used

11. Power: 220-240v6A 50 or 60Hz

12. Weight: 31Kg (No liquid in the groove)

13. Demension: 41x52x42cm

 